ProbeerIP67AfschermingRoHSTrillingenRF-connector

12 resultaten voor “RF connector”

  1. 01

    Productkennis10 min lezenEngelstalig

    RF connector selection and signal integrityHow impedance, connector family, return loss, insertion loss and passive intermodulation determine the performance of a coaxial link. A practical guide to choosing RF connectors and cable, reading their specifications and avoiding the mating and handling errors that degrade signal integrity.
  2. 02

    Technische gidsen11 min lezenEngelstalig

    Connector selection for high-vibration environmentsVibration rarely breaks a connector outright; it degrades the contact interface through micromotion, fretting and intermittent interruptions. This guide explains the failure mechanisms, the connector and cable features that resist them, and how sinusoidal, random and shock tests are used to qualify a connection.
  3. 03

    Technische gidsen10 min lezenEngelstalig

    How to select an industrial connectorA structured way to choose an industrial connector: define the electrical load, the mechanical and environmental conditions at the connector, the termination and the mating regime, then let each requirement rule out connector families. Ratings are only meaningful together with the conditions under which the datasheet states them.
  4. 04

    Normen & compliance10 min lezenEngelstalig

    Understanding IP ratings for connectorsThe IP code of IEC 60529 states how well an enclosure keeps out solid objects and water under defined test conditions. For connectors, the code is only meaningful together with the state in which it was tested — mated, unmated or capped — and it says nothing about temperature, chemicals or seal ageing. ISO 20653 adds K-suffixed codes such as IPX9K for road vehicles.
  5. 05

    Engineering-inzichten9 min lezenEngelstalig

    Shielded vs unshielded connectorsA shield only improves electromagnetic compatibility when it is continuous from cable to housing to panel, with low impedance at the frequencies that matter. This article explains how foil and braid shields work, what transfer impedance measures, why 360° termination outperforms pigtails, how to approach shield grounding, and when an unshielded connection is the better engineering choice.
  6. 06

    Applicatienotities8 min lezenEngelstalig

    Connector solutions for medical equipmentConnectors in medical electrical equipment form part of the means of protection that IEC 60601-1 requires, and they must survive daily cleaning, repeated mating and, in some cases, sterilisation. This note covers insulation and spacing, mis-mating prevention, chemical resistance, biocompatibility and the documentation a device maker needs from its interconnect supply chain.
  7. 07

    Productkennis9 min lezenEngelstalig

    Understanding connector datasheetsEvery value on a connector datasheet is valid only under the conditions it was determined in. This guide explains how to read electrical, mechanical and environmental ratings, derating curves, materials, approvals and ordering codes — and which questions to ask when the datasheet does not answer them.
  8. 08

    Applicatienotities8 min lezenEngelstalig

    Reliable connectivity in automotive applicationsVehicle connectors must keep a low, stable contact resistance through years of vibration, temperature cycling and exposure to fluids, while being assembled at line speed. This note covers the environmental loads, the test philosophy behind USCAR-2 and LV 214, assurance features such as TPA and CPA, and the extra requirements of high-voltage and high-speed data connections.
  9. 09

    Normen & compliance10 min lezenEngelstalig

    ECCN and HS classification explainedAn HS code describes what a product is for customs duty and trade statistics; an ECCN or EU dual-use entry says whether its export is controlled. This note explains both systems as they apply to connectors, cable and cable assemblies, and how they differ from country of origin.
  10. 10

    Engineering-inzichten9 min lezenEngelstalig

    Contact resistance and connection reliabilityContact resistance is set by a few microscopic contact spots and the films that cover them, not by the apparent contact area. This article explains constriction and film resistance, the roles of normal force, wipe and plating, how contact resistance is measured, and how it links to temperature rise and current derating.
  11. 11

    Technische gidsen9 min lezenEngelstalig

    Cable assembly design considerationsA cable assembly is a small system: conductors, insulation, jacket, shielding, terminations, connectors and strain relief that must work together for the life of the equipment. This guide covers requirements capture, material and termination choices, testing and the documentation that makes an assembly reproducible.
  12. 12

    Normen & compliance10 min lezenEngelstalig

    RoHS and REACH explainedRoHS restricts ten substances in electrical and electronic equipment; REACH regulates chemicals in the EU and, for articles such as connectors and cables, creates a duty to communicate Candidate List substances above 0.1 % by weight. This article explains scope, thresholds, exemptions, the SCIP database and what a supplier declaration does and does not tell you.

Engineering-ondersteuning

Een vraag die geen artikel beantwoordt?

Stuur ons uw toepassing, tekening of onderdeelnummer. Een specialist van Belko helpt u de juiste verbinding te bepalen.