Cable assembly design considerations

A cable assembly is a small system: conductors, insulation, jacket, shielding, terminations, connectors and strain relief that must work together for the life of the equipment. This guide covers requirements capture, material and termination choices, testing and the documentation that makes an assembly reproducible.

Reading time
9 min read
Technically reviewed
11 October 2026
Document
Rev. 1
Level
Intermediate
Fig. 00 — Technical Guides

Most cable assembly problems are decided before anything is cut or crimped. A jacket that hardens in the cold, a conductor sized for current but not for voltage drop, a solder joint where the cable flexes, a drawing that does not say where length is measured from — each looks minor on paper and becomes expensive in the field. This guide walks through the decisions in roughly the order they should be made, from the requirements to the documentation that lets an assembly be built the same way every time.

Start with the requirements

A good requirements set describes what the assembly must survive and do, not only what it should look like. The questions below cover the information an assembly supplier needs to propose a construction; unanswered questions are not a problem in themselves, as long as they are recognised as open rather than silently assumed.

  1. 01Function and interfaces: what does the assembly connect, and which mating connectors, pinouts and polarisation are fixed by the equipment at each end?
  2. 02Electrical load: current per circuit (continuous and peak), voltage between circuits and to earth, signal types (power, analogue, digital data, RF).
  3. 03Signal integrity and EMC: controlled impedance, twisted pairs, shielding requirements and how the shield is terminated at each end.
  4. 04Mechanical duty: fixed installation, occasional handling, continuous flexing in a cable chain, or torsion on a robot axis.
  5. 05Environment: temperature range, oils, coolants, cleaning agents, UV, water and the required IP rating of the mated connectors.
  6. 06Length and routing: overall length and tolerance, breakout lengths, minimum bend radius available in the installation.
  7. 07Regulatory and market: RoHS/REACH, flame-retardance or halogen-free requirements, industry-specific standards and approvals required for the end product.
  8. 08Workmanship and test: acceptance class, electrical tests and whether test records are required per assembly.
  9. 09Identification: labelling, traceability level (batch or serial) and customer part number.
  10. 10Volume and life cycle: prototype quantities, series volumes, expected product life and tolerance for alternative components.

Conductors, insulation and jacket

Conductor sizing

Conductor cross-section is set by three separate limits, and the largest of the three wins. Temperature rise: the current a conductor can carry depends on insulation temperature rating, ambient temperature and how many loaded conductors share the jacket — a multicore cable carries less per conductor than a single wire in free air. Voltage drop: long runs at low voltage are often limited by drop, not heating. Mechanical: very small cross-sections are fragile and may fall below the range of the intended crimp contact. Conductor stranding matters as much as size: IEC 60228 distinguishes solid (class 1), stranded (class 2), flexible (class 5) and extra-flexible (class 6) conductors, and anything that moves needs the finer classes.

Insulation and jacket materials

The jacket protects everything inside it from the environment, and in many assemblies it is the first component to fail. Material families have characteristic strengths, but properties vary considerably between compounds within each family; the cable manufacturer's datasheet for the actual compound governs temperature range, oil resistance and flex performance.

Tab. 1Common insulation and jacket materials (general characteristics; compound-dependent)
MaterialStrengthsLimitationsTypical use
PVCEconomical, easy to process, wide range of compoundsStiffens at low temperature; contains halogen; limited oil resistance unless specially compoundedFixed installation, equipment wiring, general-purpose cables
PUR (polyurethane)Abrasion, cut and oil resistance; good flex lifeHigher cost; hydrolysis resistance depends on the gradeCable chains, machine tools, robotics, sensor cables
TPEFlexible over a wide temperature range; can be halogen-free; good for overmouldingAbrasion and oil resistance vary strongly with gradeIndustrial and medical cables, overmoulded assemblies
PTFE / FEP / ETFE (fluoropolymers)High temperature, chemical resistance, low loss, thin wallsStiffer; costly; difficult to bond for overmouldingAerospace, high-temperature and RF/coax applications
SiliconeVery flexible, wide temperature range, tolerates repeated sterilisationLow tear and abrasion resistanceMedical devices, high-temperature zones
Halogen-free flame-retardant compoundsLow smoke and no halogen acid gas in fireMechanical properties vary; often less oil resistantRail, public buildings, enclosed spaces

Shielding

Foil shields give full coverage and are effective at high frequencies but tolerate little flexing; braids give lower coverage, better low-frequency performance and better flex life; combined foil and braid is common in data and instrumentation cables. A shield is only as good as its termination: a full 360° connection to the connector housing performs far better than a drain wire or pigtail. The details are in shielded vs unshielded connectors.

Bend radius and flex life

Cable manufacturers state a minimum bend radius, usually as a multiple of the cable's outer diameter and often with separate values for fixed installation and for continuous movement. The value for movement is always larger. Bending tighter than specified stretches conductors on the outside of the bend, compresses insulation on the inside and, in shielded or coaxial cables, changes the geometry that sets impedance and shielding.

Flex life — the number of movement cycles a cable survives — is not a single number but the result of a specific test: bend radius, travel, speed, acceleration and the failure criterion all matter. Values from one manufacturer's test cannot be compared directly with another's. Cables for cable chains are designed for bending in one plane; cables for robot dress packs must also withstand torsion, which is a different construction. Specify the movement type, and ensure the motion happens in the cable, not at the connector.

Terminations, overmoulding and strain relief

Termination methods

Crimp

The default for industrial and automotive assemblies

  • Gas-tight cold-welded joint when tool, die, contact and wire are matched.
  • Repeatable; quality verified by crimp height, pull force and cross-section analysis.
  • IEC 60352-2 covers general requirements, test methods and practical guidance for crimped connections.
  • Requires the correct tool for each contact; hand tools must be the type the contact manufacturer specifies.

Solder

Common for PCB-style cups and RF centre contacts

  • Suited to low volumes and contacts designed as solder cups.
  • Solder wicks into the strands and creates a rigid zone where flexing concentrates.
  • Quality depends heavily on operator skill and process control.
  • Avoid tinned wire ends in crimp or screw terminals: solder cold-flows under pressure and the connection loosens.

IDC

Insulation displacement for ribbon and multi-way signal connections

  • Terminates many conductors at once without stripping.
  • Requires conductor size and insulation within the contact's specified range.
  • Generally used for signal-level currents and fixed installations.

IEC 60352-2 (current edition 2024) applies to crimped connections on stranded wires from 0.05 mm2 to 10 mm2 and solid wires from 0.25 mm to 3.6 mm diameter, and gives tests for judging their stability under mechanical, electrical and climatic stress. It does not cover crimping of coaxial cables: RF connector crimps follow the connector manufacturer's instructions for strip dimensions, ferrule and die. In production, crimp quality is controlled by verifying crimp height on set-up and at intervals, by pull testing, and by periodic cross-sections.

Overmoulding encapsulates the connector-to-cable transition in a moulded body. It adds sealing, strain relief and a robust handle, but it is permanent and needs a tool. The overmould compound must bond to, or mechanically lock onto, the cable jacket — similar material families bond well, fluoropolymers poorly — and moulding pressure and temperature must not damage internal terminations. Strain relief in non-moulded assemblies comes from cable clamps in the backshell or housing, heat-shrink boots or cable glands; the clamp should grip the jacket, not the conductors, so that pulling on the cable never loads the contacts.

Labelling should survive the life of the assembly: printed heat-shrink sleeves or laminated labels rather than paper. A label typically carries the part number with revision and a date or batch code; where traceability matters, a serial number links the assembly to its test record.

Workmanship and testing

IPC/WHMA-A-620, Requirements and Acceptance for Cable and Wire Harness Assemblies, is the industry-consensus workmanship standard for crimped, mechanically secured and soldered interconnections in cable and harness assemblies (revision E was released in 2022). It defines three product classes — Class 1 general electronic products, Class 2 dedicated service products, and Class 3 high-performance or harsh-environment products — with progressively stricter acceptance criteria. State the class on the drawing; if no class is stated, the supplier and customer may assume different ones.

Tab. 2Common electrical tests for cable assemblies
TestWhat it findsPoints to specify
ContinuityOpen circuits and wrong connectionsResistance threshold; whether every circuit is tested
Short / isolationShorts between circuits and to shieldResistance threshold between all circuit combinations
Insulation resistanceDegraded or contaminated insulationDC test voltage, minimum resistance, dwell time
Dielectric withstand (hipot)Insufficient clearance, damaged insulation, trapped strandsAC or DC, test voltage, duration, leakage current limit
RF tests (coax)Termination quality and impedance discontinuitiesVSWR or return loss and insertion loss over the frequency band

Test voltages and limits come from the product requirements and the ratings of the cable and connectors, not from a general rule. Hipot at levels above the components' ratings damages the parts it is meant to verify.

Electrical testing of every assembly is normal practice for continuity and shorts and is inexpensive with an automated tester. Mechanical checks — crimp height, pull tests, visual inspection to the agreed class — are usually done at set-up and on a sampling basis. For a new design, a first-article inspection against the drawing confirms that the documentation and the product agree before series production starts.

Documentation

What a cable assembly drawing should contain

Overall length
Value, tolerance and the reference points it is measured between
Breakouts
Lengths and tolerances of each leg and the position of transitions
Wiring table
Pin-to-pin connections, wire colours, twisted pairs, shield termination at each end
Bill of materials
Manufacturer part numbers for cable, connectors, contacts, backshells, sleeving and labels; approved alternatives if any
Workmanship
IPC/WHMA-A-620 class and any customer-specific requirements
Testing
Tests, parameters, limits and whether records are kept per assembly
Marking and packaging
Label content and position; coiling, bagging and quantity per package
Revision
Revision level and change history

Approved alternatives in the BOM give flexibility when a component becomes scarce; leaving them out locks the design to a single source.

Connector and contact choices for the ends of the assembly follow the same logic as any connector selection — see how to select an industrial connector, and for coaxial assemblies RF connector selection and signal integrity. An experienced cable assembly specialist can help turn an incomplete requirement into a buildable construction.

Key takeaways

  1. 01Capture requirements as conditions to survive and functions to perform; mark open points explicitly instead of letting them be assumed.
  2. 02Size conductors for temperature rise, voltage drop and mechanical robustness, and match stranding class to movement.
  3. 03Choose the jacket for the environment and movement, and confirm properties on the compound's datasheet.
  4. 04Keep movement away from terminations; crimp to the contact manufacturer's tooling, and do not put solder where the cable flexes.
  5. 05Specify the IPC/WHMA-A-620 class, the electrical tests with their limits, and a drawing complete enough to build from without questions.

References

  1. [1]IEC 60352-2:2024 — Solderless connections – Part 2: Crimped connections – General requirements, test methods and practical guidance — International Electrotechnical CommissionScope of crimped connections, wire ranges, exclusion of coaxial cables.
  2. [2]IPC/WHMA-A-620E — Requirements and Acceptance for Cable and Wire Harness Assemblies — IPC / Wire Harness Manufacturer's Association (WHMA)Workmanship and acceptance criteria; release of revision E.
  3. [3]IEC 60228 — Conductors of insulated cables — International Electrotechnical CommissionConductor classes 1, 2, 5 and 6.
  4. [4]Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS), as amended by Delegated Directive (EU) 2015/863 — European UnionMaterial compliance requirement captured with the assembly requirements.

Apply it to your design

Need help applying this?

Send your requirements, drawing or part number. A Belko specialist reviews it with this article as context.